One step forward, one step back...
Round and round, this ain't too hard. When data have to pass to and fro, a digital cable with return channel should be used. The wave impedance is also defined as 110 O with this cable. Of the 4 wires 2 are employed for the feedback function. The robust outer jacket is suitable for outdoor and fixed installations alike. Color coding according to DIN 47100. Owing to the double shielding (AL/PT foil + Cu braid) and the wire coding it complies with the generally applicable regulations (VDE 0812/VDE 0207). Transfer speed 256 Kbs pursuant to EIA 485 standard.
Advantages:
- Digital transmission over long distances due to the DMX and AES/EBU standards
- Excellent protection against electric interference (Cu mesh screen + AL/PT foil)
- Extremely robust due to the special tough jacket
Application:
- Networking of scanners and lighting systems with check-back function
- Connection of digital control units and devices of all kinds
Article number |
540-0051 |
Name |
Binary 434 DMX512 |
EAN |
4049371002387 |
Properties |
Analog |
Properties |
Digital 110 O AES / EBU |
Properties |
OFC oxygen free copper |
Application area |
Mobile outdoor / indoor |
Application area |
ELA 100 V |
Application area |
Stage / live |
Application area |
Installation |
Application area |
Studio / Broadcast |
Application |
DMX |
Colour |
black |
Colour detailed |
black |
Signal transmission |
symmetrical |
Construction |
[2(2LI2YS0,34mm²)(ST)]CY |
Jacket material |
PVC |
Jacket Ø [mm] |
7,00 |
Number of Channels (AES/EBU, DMX) |
1 |
Inner conductor (AES/EBU, DMX) |
4 |
Inner conductor (AES/EBU, DMX) [mm²] |
0,34 |
Inner conductor Ø (AES/EBU, DMX) [mm] |
0,66 |
AWG (AES/EBU, DMX) |
22 |
Shielding |
Copper-cross mesh, tined + AL / PT foil |
Shielding factor [%] |
100 |
Copper strands (AES/EBU, DMX) |
7 |
Copper strand Ø (AES/EBU, DMX) [mm] |
0,25 |
Conductor insulation material |
PE |
Conductor insulation Ø [mm] |
1,70 |
Weight per 1 m [g] |
65 |
UV-resistant |
yes |
Fire load per m [kWh] |
0,22 |
Style variant |
round |
Packing |
100 m spool |
Temperature min. [°C] |
-25 |
Temperature max. [°C] |
70 |
Width [mm] |
7 |
[mm] |
7 |
Capac. cond./cond. per 1 m (AES/EBU, DMX) [pF] |
58 |
Capacity wire/wire at 1 ft. (AES/EBU, DMX) [pF] |
17,6784 |
Capac. cond./shield. per 1 m (AES/EBU, DMX) [pF] |
100 |
Capacity wire/electic screen at 1 ft. (AES/EBU, DMX) [pF] |
30,48 |
Impedance [O] |
110 |
Insulation resist. per 1 km [GO] |
5 |
Insulation resist. per 1000 feet [GO] |
1,524 |
Insulation resist. per 1 km (AES/EBU, DMX) [GO] |
5 |
Insulation resist. per 1000 feet (AES/EBU, DMX) [GO] |
1,524 |
Conductor resistance per 1 km [O] |
53 |
Conductor resistance per 1000 ft. [O] |
16,1544 |
Shield. resistance per 1 km [O] |
15 |
Shield. resistance per 1000 ft. [O] |
4,572 |
BPVo-Euroclass |
Fca |